Housing:
Housing IP20 according to DIN 40050
Mounting on DIN Rail 35 mm according
to DIN 46277
Material: polyamide RoHS conform
Dimensions:
(L × W × H)
Version 00: 3.9 × 4.6 × 1.77 in
(99 × 116 × 45 mm)
Versions 01, 04, 06, 07: 3.9 × 4.6 × 2.68 in (99 × 116 × 68 mm)
Supply Voltage:
24 VDC, ±20%
Power Consumption:
6 W / 8 W (Versions /01, /04, /06, /07)
Control Outputs:
Quantity: 3 opto-isolated output, passive
Voltage: max. 30 VDC:
Current: max. 30 mA
Functions: Limits, weight status
Control Inputs:
Quantity: 3, opto-isolated input, passive
Functions: zero setting, taring
Voltage: max. 30 VDC
Current: max. 10 mA
In-Output:
All I/O circuits fully galvanically isolated from sensor input and supply
Load Cell Connection:
All strain gauge load cells; 6 or 4 wire connection
Load Cell Supply:
12 V, short-circuit proof. External load cell supply possible |
Minimum Load Impedance:
Min. 75 ohm e.g. 6 load cells with 600 ohm or 4 load cells with 350 ohm
Measuring Principle:
Measuring amplifier: Delta-Sigma converter
Measuring time: min 5 ms – max. 1600 ms
Input Range:
7.5 mV (appr. 4.8 Mio. div.)
Usable resolution: 0.2 μV/d
Input Signal:
Measuring signal: 0 to 36 mV (for 100 % nominal load)
Linearity:
< 0.002 %
Temperature Effects:
Zero: TK0 m < 0.02 μV/K RTI
Span: TKspan < +/- 2 ppm/K
Digital Filter for Load Cell:
4th order (low pass), Bessel, aperiodic or Butterworth
Ethernet Interface (functions):
Ethernet IP and Modbus/TCP
Definition of an IP address: – AutoIP; – DHCP Server classification; – manual entering of an IP address
Automatic detection of signal transmission and corresponding change over (cross-over or patch cable) Webservice via SOAP|UPnP (Simple Object Access Protocol) Synchronal Modbus UDP |
Status Indicator:
Status LEDs to signal operation and error conditions.
Analogue Output:
0 to 10 or 4-20 mA, internal resolution 16-bit, usable step-width: 0.5 μA max. load 500 O; user configurable
Serial Interfaces:
RS422/485 via screw terminals
Protocol: Remote display, SMA and Minebea digital scales (XBPI–protocol)
Electrical Connections:
All electrical connections via modular screw terminals for 2.5 mm 2 max. System Phoenix/COMBICO
Temperature:
WandM: 14 °F to 104 °F (–10 °C to 40 °C)
Operation: 14 °F to 122 °F (–10 °C to 50 °C)
Storage: -40 °F to 158 °F (–40 °C to 70 °C)
Weight:
Version 00:
Net: 0.29 kg
Versions 01, 04, 06, 07
Net: 0.35 kg
Approvals:
10,000 e class III acc. to EN 45501; according to. OIML R76, min. verification interval: 0.5 μV/e |