Power:
Line voltage: 100 to 240 VAC, 50/60Hz
Optional: 9 to 36 VDCPower Consumption:
3.2W (AC) 1 × 350 ohm load cell, 15W max;
4W 4 × 350 ohm load cells or 8 × 700 ohm load cellsExcitation Voltage:
10 VDC (± 5 VDC), 8 × 350 ohm or 16 × 700 ohm load cells
Analog Signal Input Range:
-5 mV to +70 mV
Analog Signal Sensitivity:
0.3 μV/graduation minimum
1 μV/graduation recommended
A/D Sample Rate:
6.25 to 120 Hz, software selectable
Resolution:
Internal: 8,000,000 counts
Display: 1,000,000
System Linearity:
Within 0.01% full scale
Digital I/O:
Four configurable I/O, 5V logic |
(Optional) Analog Output: 16-bit resolution, voltage output 0-10 VDC, current output 0-20 mA / 4-20 mA
(Optional) Relay Board:
4 normally open dry contact relays and can switch 20-250 VAC @ 3A or 30 VDC @ 3A. Use of external fusing to limit current is recommended. Relay COM-NO are transient protected to 400V @ 600W
Communication Ports:
Two full-duplex RS-232
RS-485/422 (two-wire or four-wire)
Micro USB (device)
Ethernet TCP/IP (10/100)
Wi-Fi
Bluetooth®
Annunciators:
Zero, Gross/Net, Tare, Wi-Fi, Bluetooth®
Display:
Five-inch LCD, 800 × 480 pixel, 500 NIT
Keys/Buttons:
Flat membrane panel, tactile feel
18 buttons plus 5 softkeys and power |
Dimensions:
(L x W x H)
10.0 x 4.0 x 8.6 in
(254 x 102 x 218 mm)Temperature Range:
Certified: 14 °F to 104 °F (-10 °C to 40 °C)
Industrial: 14 °F to 122 °F (-10 °C to 50 °C)Rating/Material:
IP69K (IP66 with RJ45 option)
AISI 304 Stainless Steel
Weight:
6.25 lb (2.84 kg)
Warranty:
Two-year limited
Approvals:
NTEP CC 19-021, Class III/IIIL, 10,000d
Measurement Canada AM-6121C
OIML R76 2006 A NL1 19.56R3
EU Test Certificate TC11562
CE Marked
UKCA
cULus |