Accuracy:
± 0.1% +1 d of applied load
Resolution:
Max NTEP Approved Class III: 2,500 d
Max NTEP Approved Class IIIL: 5,000 d
Max Non-NTEP Approved: 10,000 d
Enclosure:
IP66 cast aluminum
Lifting Eye, Shackle & Hook:
Crosby® or equal with 360° thrust-bearing swivel hook
Design Overload:
200% Safe / 500% Ultimate (except where noted)
Functions:
Power: Turns Unit ON or OFF
Zero: Zeros applied load up to 100% of capacity (limited range in NTEP configuration)
Tare: Tares applied load and displays weight in Net mode
User: Programmable as test, total, unit, peak hold, net/gross, view total and print
Display:
Five-digit, 1.75in (44.5 mm) LCD with programmable brightness control |
Displayable Units:
Pounds or kilograms selectable
Annunciators:
COZ, Battery Level, Net, Total, lb/kg, Stability, RF and Setpoint LEDs
Power:
Battery operated, six (6) D cell 1.5V alkaline batteries or 12 volt rechargeable battery (115/230 VAC battery charger is included)
Operating Time:
Six (6) D Cell 1.5V alkaline batteries:
Up to 1,000 hours of battery life with typical use, less with RF modem
12 volt rechargeable battery: Up to 250 hours between charging with typical use, less with RF modem
Temperature Range:
Operating: -20 °F to 122 °F (-28 °C to 50 °C)
Certified: 14 °F to 104 °F (-10 °C to 40 °C)
Auto-Off Mode:
Powers off after the scale is not used for the set time (in minutes); 15, 30, 45, 60 or OFF selectable |
Auto Sleep Mode:
Power down during non-use after the set time (in minutes) and powers up with weight change or any key press; 5, 15, 30 or OFF selectable
Service Counters:
Counts number of lifts over percentage of capacity and lifts over capacity
Filtering:
OFF, LO, HI-1 or HI-2 selectable
Radio Link:
802.15.4 at 2.4 GHz
Radio Effective Range:
Typically 100 to 300 ft line of sight
Warranty:
One-year limited
Approvals:
NTEP CC 19-122: 500 to 70,000 lb
Measurement Canada AM-6198: 500 to 5,000 lb |