Specifications
Power Requirements: 100 to 240 VAC (50/60 Hz) at 0.4A Max.
Enclosure Type: Stainless steel wall or desk-mount
Enclosure Size: 9.2-in W x 7.5-in H x 3.1-in D (233-mm W x 191-mm H x 79-mm D)
Weight: 8.2 lb (3.7 kg)
Compensated Temperature Range: 14 to 104 ºF (-10 to 40 ºC)
Operating Temperature Range: -10 to 122 ºF (-23 to 50 ºC)
Humidity: 0 to 90% non-condensing
Transducer Excitation: 9.4 VDC
Signal Input Range: 1.0 mV min. to 31 mV max. (with dead load boost)
Number of Load Cells: 8 each 350-ohm load cells
Load Cell Cable Length: 1,500 feet (457 m) maximum (requires the use of sense lines). Consult factory for other requirements. 30 feet (9 m) maximum without sense lines.
Division Value Commercial: 1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001
Division Value Non-commercial: 1 to 99 x 10, 1, 0.1, 0.01, 0.001
Sensitivity Non-commercial: 0.15 uV/e
Sensitivity NTEP: 0.3uV/e (Class III/IIIL)
Sensitivity Canada: 0.3uV/e (Class III/IIIHD)
Sensitivity OIML: 0.5 uV/e (Class III)
Scale Divisions Non-commercial: 100 to 240,000
Scale Divisions NTEP: 500 to 10,000 (Class III/IIIL)
Scale Divisions Canada: 500 to 10,000 (Class III/IIIHD)
Scale Divisions OIML: 500 to 10,000 (Class III)
Internal Resolution: 1 part in 16,777,216
Tare Capacity: Scale Capacity
Sample Rate: 1 to 100 samples per second, selectable
Auto Zero Range: 0.5 or 1 through 9 divisions
Weighing Units: Tons, Pounds, Pounds-Ounces, Ounces, Metric Tons, Kilograms, Grams
Keypad: Color-coded membrane type, 22 keys
Standard I/O: 4 ea serial I/O ports configured as 1 ea 20mA output-only ports (uses one of the four RS-232 ports), 1 ea bi-directional 20mA port (uses one of the four RS-232 ports), and 1 ea USB port (uses one of the four RS-232 ports), plus 8 ea remote isolated inputs and outputs
Display: Six-digit, seven-segment, 0.6-in (15-mm) high LED